- Bin Store Odour Control Filters and Fan Filter Box April 28, 2021Continue reading →
Bin Store Ventilation is vital to minimise the build up of gases and odours which arise from rotting waste and bacteria. Failiure to ventilate a bin store sufficiently, along with other hygeine measures can lead to public health issues and also nuisance issues to local residents and passers by. To reduce risk of these issues mechanical ventilation can be used to offer a high turnover of air through the bin store with a suitable odour control filtration system to clean air prior to discharge.

Airclean offer odour control solutions for bin store ventilation systems using activated carbon which will reduce organic odours making any ventilation discharge points acceptable to local residents or passers by.
Option 1 – Filtration Only – 2 Stage Odour Control Filter System
The 2 Stage Airclean Kitchavent 2000 Odour Control System can be installed internally or externally along with a fan and ducting to ensure the discharge ventilation is acceptable for outdoor low level discharge. We offer a variation of different formations and sizes, but our low profile options generally suit bin stores where head space is usually limited.Option 2 – Fan + Filter Odour Control System
A fully integrated fan / filter unit, as standard offering airflows up to 0.3m3/s incorporating particulate and activated carbon odour control. Manufactured in a double skin Pentapost housing frame, this system is designed to offer an all in one solution to bin store ventilation. (Other air Volumes available upon request)
- Metal Framed Air Filters – What to avoid March 16, 2021Continue reading →
This is an example of a what some air filter manufacturers call a metal framed filter.
A metal framed air filter should stop a filter from warping under high moisture conditions, or prevent catastrophic failure with an air filter flying down a duct to hit a fan or other critical component.
An Airclean Metal Framed Panel Filter has no cardboard, is fully sealed, and has a backing wire to ensure the media can never fall from the filter.
Airclean Metal Framed Panel Filter
- Table-Top Laminar Flow Cabinet for Mycology February 15, 2021Continue reading →
After a surge in inquiries about our H14 HEPA filters from mycologists (cultivators of mushrooms) seeking to build DIY laminar flow cabinets. We discovered the cost of a domestic mushroom grower building a DIY laminar flow cabinet was significantly higher than we could manufacture the equipment for, while using a true H14 HEPA filters to provide the best protection.
Mushrooms and mushroom spores are vulnerable to environmental cross contamination. For the best results, mycology requires a positive pressure laminar flow of clean air from a HEPA filter to protect the mushrooms. The individually leak tested H14 HEPA included offers filtration down to 0.1 micron particulates.
With decades of experience manufacturing and selling H14 HEPA filters to hospitals and cleanrooms, we designed a versatile ductless tabletop laminar flow hood that can be bought in 3 orientation to fit your work area. The included H14 HEPA is 609 x 609 x 66mm in size providing a large area for airflow over your workspace.
For more information on our Table Top Laminar Flow Cabinet for Mycology Click Here.

How The Laminar Flow Cabinet for Mycology Works:
- Dirty ambient room air is pulled into the back of the laminar flow box.
- Larger course particles are caught in the pre filter to help keep the Fan and HEPA clean.
- Air is filtered through a H14 HEPA filter, filtering out up to 99.995% of partials down to 0.1 microns.
- The clean are is discharged, crating a particle-free work area.
- 2020 Annual Christmas and New Year Break December 11, 2020Continue reading →

2020 Annual Christmas and New Year Break
Closed: 5:00pm Tuesday 22nd December 2020
Open: 8:00am Monday 4th January 2021Where you have goods that you require before the Christmas break please get your orders to us as soon as possible.Speak to the Sales Team if you have any specific requirements.
Don’t forget those early January orders. We are already programming our schedules for our first weeks back!
Please contact us on:
Tel: 01622 832777 or Email: sales@airclean.co.uk.Finally we would like to say a BIG THANK YOU to the Customers and Suppliers that we have worked with this year.

- Ducted Options for H14 HEPA Air Purifier August 3, 2020Continue reading →
Negative Pressure Room – Safe Discharge
The Airclean H14 HEPA Air Purifier can be supplied with a ducted outlet to the top of the unit. This allows the unit to be set up to discharge through a wall, or window creating a negative pressure. This function can be used in hospitals or carehomes to prevent infection spread, whilst ensuring the discharged air is safe.HEPA Clean Air for Fan Coil AC Systems
The H14 HEPA Air Purifier can also be mounted in a room and ducted to supply fresh clean air to the back of existing fan coil air conditioning. The fan in the Air Purifier allows the system to be balanced, allowing existing fan coil fans, to handle the strain.